您的位置:首頁 > 產(chǎn)品展廳 > 儀器儀表 > 流量儀表 > 其他分析儀器 > Atomic Absorption Spectrophotometer
features:
. phase difference corrected monochromator, provide optimized optical path for entire wavelength.
. built-in 6 lamp turret, with 2 lamps (operation lamp and preparation lamp) simultaneously lightening.
. equipped with innovative and unique deuterium background correction (patent pending) for entire wavelength range.
. combustion gas cooling burner head is innovated newly and is applying patent. this technique could reduce much heating balancing time at the burner head.
. high safety air-acetylene flame facilitates 35 common elements analyzed at low operation cost.
. genius database system allows you to access index and abstracts of large amount of chinese and english literature.
complete automation on
. alignment and fine adjustment in hollow cathode lamp position.
. wavelength scan control and peak search and slit width se-lection.
. optimization of photomultiplier gain.
. energy balance between deuterium lamp and hollow cathode lamp.
. flame ignition (on/ off) as well as acetylene-o2 gas flow rate setting to optimize combustion ratio.
. optimization of analytical conditions for se-lected element simply by a mouse-click while six elements can downloaded simultaneously.
high safety
. fully automated gas control and integrated safety check yield the safest flame aa system available today.
. incorporated with air pressure sensor, acetylene gas flow will be cut in case of accident.
. combination of safety-designed burner head, special drainage system and pressurized valve control spray chamber.
. with presence of high pressure gas leakage check, it ensures automatic disconnection of gas lines in case of acetylene build up accidentally.
specifications
photometry: single-beam monochromator with grating of 1,800 lines/mm
wavelength range: 190 ?? 900 nm
bandwidth: 0.2, 0.4, 0.7, 1.4 nm
wavelength accuracy: ≤±0.45 nm
wavelength repeatability: ≤ 0.2 nm
resolution: ≤ 0.3 nm
baseline stability: ≤ 0.005a / 30 min (cu)
characteristic mass: cu ≤ 0.05 μg / ml / 1%
detection limit: cu ≤ 0.008 μg / ml
background correction: d2 lamp for entire wavelength, with correction of 30 times background
Atomic Fluorescence Spectrometer
AFS-3100 〈br〉Fully-Automatic Double-channel Atomic Fluorescence Spectrometer〈br〉
Atomic Absorption Spectrophotometer
The Accusys 211 AAS is the next evolution of the highly successful Buck 210-VGP ,
Atomic Absorption Spectrophotometer
The 210VGP is shipped ready for use. All operating conditions are preloaded in the internal computer
① 凡本網(wǎng)注明"來源:易推廣"的所有作品,版權(quán)均屬于易推廣,未經(jīng)本網(wǎng)授權(quán)不得轉(zhuǎn)載、摘編或利用其它方式使用。已獲本網(wǎng)授權(quán)的作品,應(yīng)在授權(quán)范圍內(nèi)
使用,并注明"來源:易推廣"。違者本網(wǎng)將追究相關(guān)法律責(zé)任。② 本網(wǎng)凡注明"來源:xxx(非本網(wǎng))"的作品,均轉(zhuǎn)載自其它媒體,轉(zhuǎn)載目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點(diǎn)和對其真實(shí)性負(fù)責(zé),且不承擔(dān)此 類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。如其他媒體、網(wǎng)站或個(gè)人從本網(wǎng)下載使用 ,必須保留本網(wǎng)注明的"稿件來源",并自負(fù)版權(quán)等法律責(zé)任。
③ 如涉及作品內(nèi)容、版權(quán)等問題,請?jiān)谧髌钒l(fā)表之日起兩周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。
④易推廣頁面顯示產(chǎn)品信息均由企業(yè)自主發(fā)布,信息內(nèi)容真實(shí)性、準(zhǔn)確性與合法性由相關(guān)企業(yè)負(fù)責(zé),易推廣對此不承擔(dān)任何責(zé)任,如遇非法或侵權(quán)信息歡迎監(jiān)督,請聯(lián)系QQ:1273397930或者發(fā)郵件至:1273397930@qq.com,如有確實(shí)證件證明屬實(shí),本站將對其刪除處理,謝謝!
⑤ 本信息由注冊會員:Shantou Keyi instrument & Equipment co.ltd發(fā)布并且負(fù)責(zé)版權(quán)等法律責(zé)任。
易推廣客服微信