價格詳細資料:試劑盒價格電議,齊一生物銷售:021-6034 8496;181214 53965;173021 04490,齊一生物科技(上海)有限公司提供ELISA試劑盒受到了廣大研究所.中科院科研單位一致肯定和認同。齊一生物大品牌保證,傾力為國內(nèi)外科研院校實驗室提供*優(yōu)質(zhì)產(chǎn)品。
1. 當混合蛋白溶液時應盡量輕緩,避免起泡。
2. 洗滌過程非常重要,不充分的洗滌易造成假陽性。
3. 一次加樣時間控制在5分鐘內(nèi),如標本數(shù)量多,推薦使用排槍加樣。
4. 請每次測定的同時做標準曲線,做復孔。
5. 如標本中待測物質(zhì)含量過高,請先稀釋后再測定,計算時請*后乘以稀釋倍數(shù)。
6. 在配制標準品、檢測溶液工作液時,請以相應的稀釋液配制,不能混淆。
7. 底物請避光保存。
8. 不要用其它生產(chǎn)廠家的試劑替換試劑盒中的試劑。
FOR RESEARCH USE ONLY
Drug Names
Generic Name:
This kit can be used for determination of serum, plasma and liquid samples Organization Content.
The experimental principle:
The product levels were measured in samples of the kit by double antibody sandwichmethod. The product with the purified antibody coated microtiter plate, made of solid phase antibody, to package is the product antigen monoclonal antibodies are then added to the micropores, the product and then with HRP labeled antibody binding, the formation of antibody - antigen - antibody complex enzyme label, after thorough washing with TMB chromogenic substrate. TMB in the HRP enzyme catalytic conversion into the blue, and in the action of acid into the final yellow. This product is positively related to the depth of color and in the samples. Instrument measured absorbance in the 450nm wavelength with ELISA (OD), the product concentration in the samples was calculated by standard curve.
Materials provided with the kit
Materials provided with the kit 96 determinations Storage
User manual 1
Closure plate membrane 2
Sealed bags 1
Microelisa stripplate 1 2-8℃
Standard:360ng/L 0.5ml×1 bottle 2-8℃
Standard diluent 1.5ml×1 bottle 2-8℃
HRP-Conjugate reagent 6ml×1 bottle 2-8℃
Sample diluent 6ml×1 bottle 2-8℃
Chromogen Solution A 6ml×1 bottle 2-8℃
Chromogen Solution B 6ml×1 bottle 2-8℃
Stop Solution 6ml×1 bottle 2-8℃
wash solution (20ml×30 fold)
×1bottle 2-8℃
Specimen requirements
1. serum- coagulation at room temperature 10-20 mins,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again. 【人β乳糖蛋白抗體IgGELISA試劑盒】
2. plasma-use suited EDTA or citrate plasma as an anticoagulant,mix 10-20 mins ,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.
3. Urine-collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again. The Operation of Hydrothorax and cerebrospinal fluid Reference to it.
4. cell culture supernatant-detect secretory components, collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant,detect the composition of cells, Dilut cell suspension with PBS(PH7.2-7.4), Cell concentration reached 1 million / ml, repeated freeze-thaw cycles, damage cells and release of intracellular components, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.
5. Tissue samples- After cutting samples, check the weight,add PBS(PH7.2-7.4), Rapidly frozen with liquid nitrogen, maintain samples at 2-8℃ after melting,add PBS(PH7.4), Homogenized by hand or Grinders, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant.
6. extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
7. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
Assay procedure
1.Dilute and add sample to Standard: set 10 Standard wells on the ELISA plates coated, add Standard 100μl to the first and the second well, then add Standard dilution 50μl to the first and the second well, mix; take out 100μl form the first and the second well then add it to the third and the forth well separately. then add Standard dilution 50μl to the third and the forth well ,mix ; then take out 50μl from the third and the forth well discard, add 50μl to the fifth and the sixth well ,then add Standard dilution 50μl to the fifth and the sixth well, mix ; take out 50μl from the fifth and the sixth well and add to the seventh and the eighth well, then add Standard dilution 50μl to the seventh and the eighth well ,mix ; take out 50μl from the seventh and the eighth well and add to the ninth and the tenth well, add Standard dilution 50μl to the ninth and the tenth well, mix , take out 50μl from the ninth and the tenth well discard(add Sample 50μl to each well after Diluting ,(density: 240ng/L,160ng/L ,80ng/L,40ng/L, 20ng/L)
2.add sample:Set blank wells separately (blank comparison wells .don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix. 【人β乳糖蛋白抗體IgGELISA試劑盒】
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
4.Configurate liquid: 30-fold (or 20-fold)wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
5.washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme:Add HRP-Conjugate reagent 50μl to each well, except blank well.
7.incubate:Operation with 3.
8.washing:Operation with 5.
9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
11.assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
Important notes
1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 mins, if the number of sample is much , recommend to use Volley . 【人β乳糖蛋白抗體IgGELISA試劑盒】
4. if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.
6. The substrate evade the light preservation.
7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
8. All samples, washing buffer and each kind of reject should according to infective material process.
9. Do not mix reagents with those from other lots.
Calculate:
Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.
|
Storage and validity
1.Storage: 2-8℃.
2.validity: six months.
9241148Transport lock, Y axis, M48CNY
9241143Application AUTOPURE (customized)CNY
9241005QIArent&go - Rent out fee BR UniversalCNY
9240987Kit, electronic, FFC-plugs, QsymCNY
9240980Sensor, tray, sample tracking, QsymCNY
9240945Sensor, xy, portal, QsymCNY
9234856Tubing coupling piece for washer liquidCNY
9234852Card, ISDN, Fritz PCICNY
9240783Update, Weigh Cell, AP96CNY
9240774Assy, Transfer Rack, AP96CNY
9241632LED Light System, APCNY
9241369Temperature Controller, EZ1aCNY
9243645Guided Valid Support, QIA Extraction SysThe QIAGEN Other Extraction System Guided Validation Support service includes all travel and labor charges for a site visit up to 2 days by a QIAGEN Specialist. A QIAGEN specialist will provide an introduction to QIAGEN extraction chemistry utilized in the process, review the appropriate Handbook and User Manual, as well as hands-on chemistry and instrument operation as required. The Guided Validation service includes experimental design consultation, internal validation documentation support, and QIAGEN sponsored data templates. The QIAGEN Specialist will also aide the customer in running some samples to initiate the validation process. Enough consumable chemistry and accessories (QIAGEN or other vendors) should be purchased by the customer to cover the validation experimental design and are not included in the cost of validation support. Please indicate which protocols to validate (Biosprint 96, DNA mericon)CNY
9243542BR MDx, PM Service"Service response time (repair): not applicable
Periodic inspection/maintenance: yes
Inspection/maintenance delivery: onsite
Cost coverage for Repair Parts : not included
Cost coverage for labor: yes, full coverage
Cost coverage for travel: yes, full coverage
Replacement system (Loaner) provision: not applicable
Transportation cost coverage: yes, full coverage"CNY
9243305Power Cord, IndiaCNY
9243110CD-RW, Black, AP196/98CNY
9242712Validation Support, 2d QIAcubeThe QIAGEN QIAcube Guided Validation includes all travel and labor charges for a site visit up to 2 days by a QIAGEN Specialist. A QIAGEN specialist will provide an introduction to the QIAcube system and the DNA Investigator silica chemistry utilized in the process, review the Handbook and User Manual, as well as hands-on QIAcube operation. The Guided Validation service includes experimental design consulation, internal validation documentation support, and QIAGEN sponsored data templates. The QIAGEN Specialist will also aide the customer in running some samples to initiate the validation process. Enough consumable chemistry and accessories (QIAGEN or other vendors) should be purchased by the customer to cover the validation experimental design and are not included in the cost of validation support. Please indicate which protocols to include in the validation (QIAamp, QIAamp DNA Investigator, MinElute PCR Cleanup, etc.)CNY
9019226Fan - rear 92x92, PyroQ24CNY
9019220PCB - Distribution robot, PyroQ96MDCNY
1066843PG Influenza A RT-PCR Assay (48) LE ZCNY
1066848NDV Univ. RT-PCR REAGENT LECNY
1066854AIV-H9 RT-PCR REAGENT LECNY
1060992Buffer MW1 (77ml)CNY
1061059Sample Preparation Reagents, 8mlCNY
1061080NG Quantification StandardsCNY
1061113PG AIV-H7 RT-PCR Assay (48) ZCNY
9016568Plate Grippers, RCS1CNY
9016536Transportation box , BioSprint 15CNY
9016535Transportation box , Twister IICNY
9016533Transportation box , RapidPlate onlf.CNY