產(chǎn)品展示
血站專用離心機(jī) 大容量冷凍離心機(jī)
點(diǎn)擊次數(shù):2229發(fā)布時(shí)間:2009/11/2 0:00:00

更新日期:1900/1/1 0:00:00
所 在 地:日本KUBOTA
產(chǎn)品型號(hào):KUBOTA9900型
優(yōu)質(zhì)供應(yīng)
詳細(xì)內(nèi)容
應(yīng)用范圍:血站專用離心機(jī)、醫(yī)用離心機(jī)、血液分離心機(jī)、血小板離心機(jī)心機(jī)、生物制藥離心機(jī)、中試離心機(jī)、放免離心機(jī)
行業(yè):血庫(kù)專用離心機(jī)、血站專用離心機(jī)、醫(yī)用離心機(jī)、醫(yī)藥離心機(jī)、制藥離心機(jī)、藥廠離心機(jī)
推廣:落地式大容量冷凍離心機(jī)
產(chǎn)品配置:
In choosing a centrifuge able to accept blood bags, the 9900 model is the best choice. The RS-7002 rotor and the RS-6602 rotor can spin 6 x 400mL quadruple blood bags. In addition, the 9900 is equipped with several functions designed for blood-bag centrifugation. For example, the acceleration and deceleration function (with 10 switching levels) is installed, while the super slow mode can avoid whirring up immediately before the centrifugal termination.
If testing a large volume of samples with high g-force is the primary use, the 9900 model is the ideal choice. Some experiments, such as cell collection, require both large volume and high g-force. The S12510 rotor is able to spin 6 x 1,000mL bottles over 8,000xg. The rotor saves the total experiment time, reaching the maximum speed and in about three minutes.
If complying with GMP (Good Manufacturing Practice) is required, the 9900 model is highly recommended. Various optional choices, such as PC connection, mounting a log printer, and a barcode reader, are available to meet stringent GMP requirements.
Maximum speed
6,000rpm
Maximum RCF
8,291xg
Maximum capacity
6,600mL
Control system
Microprocessor control, Induction motor (Brushless motor), Speed, RCF, Time, g-sec, Temperature, Acceleration & Deceleration, Memory (99 channels)
Abnormality detected display
Lid open, Imbalance, Over speed, Abnormally high temperature, Function for detecting an occurrence of electrical abnormality in motor, Inverter, Lid interlock sensor, Speed sensor, Temperature sensor
Acceleration/Deceleration
ten-level selectors
Speed setting
From 100 to 6,000rpm, 10rpm increments
Speed indication
Digital display, from 100 to 6,000rpm, 10rpm increments
RCF setting
From 10 to 8,291xg, 1xg increments
RCF indication
Digital display, from 0 to 8,291xg, 1xg increments
Integrator setting and indication
Digital display, from 1.00 to 9.99 x1010 g.sec
Timer setting and indication
Digital display, with Hold and Electric buzzer
from 1 sec. to 59 min. 59 sec., in 1 sec. increment setting
from 1 min. to 99 hours 59 min., in 1 min. increments setting
Temperature setting and indication
Digital display, 0.1°C increments setting and indication
Ordinary model: from -20°C to 42°C
Brake system
Ten-level selectors
Power requirements
Single phase AC220V+10%-5%, 230V+10%-5%, 50/60Hz, 30A
Rated voltage and Rated current
Single phase AC220/230V, 50/60Hz, 15A
Power consumption and heat output
2,200W, 7.9MJ/h
Dimensions (WxDxH) and Weight
710x830x1150mm, 330kg
聯(lián)系方式:
聯(lián)系人:王晴川
電 話:010-84945674-804
傳 真:010-84945674-801
手 機(jī):13810336712
EMAIL: Rvmail@sohu.com
QQ:928847017
MSN:vincasia@hotmail.com
| | In choosing a centrifuge able to accept blood bags, the 9900 model is the best choice. The RS-7002 rotor and the RS-6602 rotor can spin 6 x 400mL quadruple blood bags. In addition, the 9900 is equipped with several functions designed for blood-bag centrifugation. For example, the acceleration and deceleration function (with 10 switching levels) is installed, while the super slow mode can avoid whirring up immediately before the centrifugal termination. |
|