變頻器:麥格米特、臺達(dá)、歐姆龍、施耐德、ABB、西門子、A-B、三菱、GE、艾默生
儀表類的品牌:阿美特克 E+H流量計、UE壓力開關(guān)、CCS壓力開關(guān)?SOR壓力開關(guān)、霍尼韋爾變送器、羅斯蒙特變送器?E+H儀表
Rated Output
額定輸出
2.0mV/V ±0.1%
Zero Balance
零點平衡
±1% of rated output
Creep after 30 minutes
蠕變
±0.03% of rated output
Nonlinearity
非線性
±0.03% of rated output
Hysteresis
滯后
±0.03% of rated output
Repeatability
重復(fù)性
±0.03% of rated output
Temp. effect on output
靈敏度溫漂
≤0.002% of applied output/oC
Temp. effect on zero
零點溫漂
≤0.002% of rated output/oC
Safe Temp. Range
可用溫度范圍
-10oC to + 70oC
Temp. Compensated
溫度補(bǔ)償范圍
-10oC to + 40oC
Safe Overload
安全載荷
150%
Input Impedance
輸入阻抗
387 ohm ± 20 ohm
Output Impedance
輸出阻抗
350 ohm ± 5 ohm
Insulation Resistance
絕緣阻抗
≥5000 M ohm (50V DC)
Rated Excitation
推薦激勵電壓
10V DC/AC
Maximum Excitation
激勵電壓
15V DC/AC
Cable Length
導(dǎo)線長度
3m
Cable Color Code
導(dǎo)線顏色
Red(+E) Black(-E) Green(+S) White(-S)
江威工程師指出RTN傳感器調(diào)試注意事項:
(1)調(diào)試時,要檢查每一個參數(shù)出廠設(shè)定值是否符合實際需要,尤其是"開
機(jī)清零"參數(shù),出廠時一般都設(shè)定為"開機(jī)自動清零",在容器秤上改為"禁止
開機(jī)自動清零",防止因停電等原因,再次開機(jī)時,容器的物料重量被清零而丟
失。
(2)量程設(shè)定不是指一套稱重模塊的額定總負(fù)荷,也不包括容器自身的重量
,而應(yīng)根據(jù)物料稱量,從說明書所給的分度數(shù)和分度值中選取大于等于
稱重量作為量程。
(3)稱重顯示儀電源電壓必須符合要求,如電壓不穩(wěn),超出允許范圍,則會
引起數(shù)字漂移。使用穩(wěn)壓電源。由于電子稱重模塊組成的稱重系統(tǒng)便于實現(xiàn)
過程自動化稱量,便于與計算機(jī)聯(lián)網(wǎng),因而在化工企業(yè)必將得到越來越廣泛的應(yīng)
用。
稱重傳感器絕緣不佳故障原因分析
【摘要】稱重傳感器使用過程中經(jīng)常遇到零點漂移、示值不穩(wěn)、數(shù)據(jù)亂跳等問題,對問題產(chǎn)品進(jìn)行檢測,主要是Z6系列精度為“D1"C3稱重傳感器絕緣阻抗不合格。因此稱重傳感器在生產(chǎn)流轉(zhuǎn)過程中必須對引起稱重傳感器絕緣不合格的各環(huán)節(jié)加強(qiáng)質(zhì)量控制。
一、引言
隨著電子衡器行業(yè)飛速發(fā)展,衡器市場日趨壯大。各種地磅、汽車衡的使用也日趨廣泛,但用戶在使用過程中經(jīng)常會遇到稱重不準(zhǔn),數(shù)字顯示儀示值不穩(wěn)定,Z6系列精度為“D1"C3觸摸稱重傳感器,出現(xiàn)跳數(shù)等故障現(xiàn)象。經(jīng)過對問題產(chǎn)品檢查,60%都是因為稱重傳感器絕緣不佳導(dǎo)致的,所以本文對造成絕緣不佳的原因及稱重傳感器生產(chǎn)制造中需注意的問題做進(jìn)一步分析。
二、概述